Interior insulation in an Altbau: the honest guide to Innendämmung
Ask an energy consultant about insulating a pre-1949 apartment building and you will hear the same sentence within minutes: "Von außen — from the outside, if at all possible." Exterior insulation is physically the cleanest solution: the warm masonry stays warm, the dew point sits harmlessly in the new insulation layer, and the heavy wall keeps acting as a thermal store. But in much of the German Altbau stock, the outside wall simply is not available to you — and that is where Innendämmung (interior insulation) enters, bringing the most demanding physics of any retrofit measure with it.
Why the outside wall is off-limits for many Altbaus
There are four common reasons, and most affected buildings have at least one of them:
- Preservation order (Denkmalschutz) or preserved stucco. A facade with ornaments, rustication or historic plaster cannot take a 10–20 cm insulation shell without destroying exactly what is protected. Restoring the stucco properly is its own craft (see stucco restoration) — covering it in polystyrene is not an option.
- Erhaltungssatzung. Many Gründerzeit quarters — whole districts of Berlin, Munich, Leipzig — sit under a preservation statute that freezes the street image. The facade may be repaired in like-for-like materials, but changing its plane or appearance typically needs a permit that will not come.
- Neighbours and building structure. In a tenement you own only your slice of the wall; exterior insulation would need the whole owner community to agree, fund and coordinate. Row and end-of-terrace houses face a related problem: insulating your gable shifts the facade plane relative to the neighbouring house.
- Building-law setbacks. Adding thickness to the outer wall can consume land you are not allowed to build on — the prescribed distance to the plot boundary (Abstandsfläche) leaves no room for the insulation layer in dense inner-city blocks.
The result is paradoxical: the buildings that would benefit most from insulation are often the ones least allowed to have it on the outside. Interior insulation is then the only remaining path — or the honest answer is to do less, but correctly (see what the grandfathering rules let you skip).
The physics in plain words
A solid brick wall with 40–60 cm of thickness holds a surprising amount of heat. Insulate it from the inside and you pull that warmth away: the wall behind the insulation becomes cold — close to outdoor temperature, in fact. Three consequences follow:
- The dew point moves into the wall. Warm indoor air carries water vapour. Wherever it meets a surface colder than its dew point, the vapour condenses. In an uninsulated wall the masonry is warm enough that condensation stays away; behind a badly planned interior insulation layer, the condensation plane now sits inside the construction — invisible, and a perfect breeding ground for mould.
- Vapour needs an exit. The classic mistake is to seal the warm side tight (foam board plus vapour-tight foil) while the cold side stays open. Moisture that gets into the wall can then no longer dry outwards or inwards and accumulates year after year. The safer rule for interior insulation is: drier on the inside, more open on the outside — capillary-active, breathable systems let the wall keep drying.
- Tau — the cold corner problem. Corners, window reveals and wall/ceiling junctions have more surface than mass; they cool faster than the flat wall. Leave them uninsulated and the "tau" (the corner) becomes the coldest spot in the room — precisely where mould appears first, even though the middle of the wall is toasty. Anyone who has fought damp and mould in an Altbau knows this geometry personally.
This is why "just stick foam on it" is the mould recipe, not a renovation. Every interior insulation job is a moisture-management design first and a thermal upgrade second.
Materials compared
No single material wins; each occupies a niche defined by thickness, vapour behaviour and budget. Rough 2026 ranges for material plus installation — treat them as orientation, not quotes:
| Material | Thickness for a meaningful effect | Cost per m² (material + install) | Vapour behaviour | Best use |
|---|---|---|---|---|
| Mineral insulation board (e.g. special calcium-silicate or mineral foam boards) | 4–10 cm | roughly €90–180 | capillary-active, very open | Good all-rounder for breathable walls, mould-prone corners |
| Calcium silicate board (CaSi) | 2–10 cm | roughly €120–220 | highly capillary-active, buffers moisture | Where mould remediation and insulation happen in one step; tight rooms |
| Wood fibre board | 4–10 cm | roughly €100–190 | open to diffusion, moisture-buffering | Ecological renovations, timber-friendly walls, good summer heat protection |
| Perlite board | 3–8 cm | roughly €80–160 | open to diffusion, non-combustible | Fire-sensitive areas, damp-prone basements and ground floors |
| Vacuum insulation panels (VIP) | 2–4 cm | roughly €250–400 | effectively vapour-tight | Only where every centimetre counts — reveals, niches; unforgiving if pierced |
The thin-but-expensive panels (CaSi, VIP) trade cost for space — decisive in rooms where losing 10 cm on each wall already hurts. The breathable boards cost less to run and forgive planning mistakes; the vapour-tight ones do not forgive anything. Experiences from completed Altbau projects point the same way again and again: the material matters less than whether the system was planned as a whole.
The detailing that decides success
Ask anyone who has done this: the failure points are never the middle of the wall. They are:
- Window reveals. A reveal insulated to 2–4 cm with thin CaSi or vacuum panels keeps the glass zone warm and stops the classic condensation stream down the reveal. Insulate the wall but skip the reveal and you have built a cold frame around your window — worth checking what new Altbau windows cost if the frames are due anyway.
- Wall/ceiling and wall/floor junctions. Where the insulated wall meets uninsulated ceilings and floors, thermal bridges concentrate. These junctions must be overlapped or bridged with thin insulation strips — otherwise the mould line runs along the ceiling edge.
- Socket boxes. Every recessed metal box is a heat leak drilled through your new insulation. Use surface-mounted or insulated special boxes, and seal around them airtight.
- Breathable vs vapour-tight systems. A capillary-active system without a vapour barrier relies on the insulation layer absorbing and passing moisture — it demands consistent materials and careful workmanship. A vapour-tight system relies on the foil never failing, ever, anywhere. In practice the breathable route is more forgiving of an old, unpredictable wall.
This detailing is also where quotes differ most. A cheap bid that skips the reveals and junctions is not cheaper — it is a deferred mould case.
Costs: a worked example
Take a typical Altbau room situation: 50 m² of exterior wall in a third-floor flat, one window wall with two deep reveals, eight sockets to relocate. Rough 2026 ranges, fully installed by a specialist firm:
| Scenario | System | Price range (50 m² wall) | What moves it |
|---|---|---|---|
| Low | Perlite or mineral board, 4–6 cm, minimal detailing | roughly €4,500–7,000 | Straight walls, few sockets, accessible room |
| Typical | Wood fibre or mineral board, 6–8 cm, reveals and junctions included | roughly €7,000–12,000 | Scaffolding-free interior work, standard detailing |
| High | CaSi, 6–10 cm, full airtightness concept, VIP reveals | roughly €12,000–20,000 | High ceilings, many sockets, tight stairwell access, mould remediation bundled in |
What reliably moves the number upwards: working heights (scaffolding inside a 4-metre room), the number of sockets and switches, deep reveals needing thin specialty panels, wallpaper and panelling to remove, and — the classic Altbau surprise — walls that turn out to be more uneven than any board will tolerate. For context against the rest of the budget, see what heating actually costs and the full renovation budget breakdown.
GEG and the U-value: what it "counts" for
The GEG (Building Energy Act) sets target U-values for exterior walls — for new insulation on old masonry, roughly in the region of U ≤ 0.24 W/(m²K) as a reference value for full upgrades. Here is the honest answer:
- Reaching that with interior insulation on solid brick usually needs 10 cm or more of good material — and thick interior insulation brings its own moisture risks. Many sensible Altbau projects deliberately install 4–8 cm and stop there.
- Interior insulation counts as a partial measure. Under GEG grandfathering rules, an existing building only triggers full upgrade obligations when a measure touches 10 % or more of an element. Insulating 50 m² of wall in one flat of a tenement is not a full facade upgrade — you improve the building, but you are not required to hit the reference value everywhere.
- Whether your measure legally triggers obligations depends on scope and building type — the Bestandsschutz rules decide the details. Have an energy consultant confirm the scope in writing before you order material.
Realistic outcome with 6–8 cm on a solid brick wall: the U-value drops from somewhere around 1.3–1.7 W/(m²K) to roughly 0.35–0.5 W/(m²K). Not new-build standard — but combined with a sensible heating strategy, it changes how the rooms feel and what the heating bill does.
When to skip it
Interior insulation is invasive, expensive per U-point and unforgiving. Consider not doing it when:
- The wall stays warm enough anyway. A 60 cm brick wall with a properly sized radiator at the wall and a heating rhythm that keeps base temperature up may never drop below the dew point. Fix the ventilation instead.
- The problem is air, not fabric. Most Altbau mould comes from under-heating plus closed windows. Correct heating and ventilating costs nothing and solves a share of cases that insulation cannot.
- Only the edges are cold. Floor-edge insulation strips at skirting height, insulated reveals and socket gaskets target the actual thermal bridges at a fraction of the cost and surface loss.
- You cannot do the detailing. If the budget covers the boards but not the reveals, junctions and airtightness work, stop. A half-detailed interior insulation is worse than none — you have relocated the condensation plane without managing it.
It almost never comes from the material — it comes from missed details. The usual suspects: uninsulated or badly sealed window reveals (cold frame around the glass), thermal bridges at ceiling and floor edges left bare, leaky socket boxes and cable ducts pushing warm humid air into the cold wall, and vapour-tight layers stopping the wall from drying outwards. Diagnose the exact spot before re-opening anything: our guide to damp and mould in the Altbau covers the patterns, and the glossary explains terms like capillary-active and diffusion-open.
Planning work on an old building?
Windows, wiring, heating, floors — model every line item before you get quotes.
Open the calculatorCost and material figures are rough orientation ranges for 2026 and vary by region, wall condition and firm. Interior insulation should be planned with a qualified energy consultant. Questions for the editors: hello@altbau.com