Building fabric

Interior insulation in an Altbau: the honest guide to Innendämmung

altbau.com editorial · Updated: November 2026 · 10 min read
Condensation on a single-glazed reveal — exactly the kind of cold surface interior insulation has to deal with. Photo: Pexels (license-free)

Ask an energy consultant about insulating a pre-1949 apartment building and you will hear the same sentence within minutes: "Von außen — from the outside, if at all possible." Exterior insulation is physically the cleanest solution: the warm masonry stays warm, the dew point sits harmlessly in the new insulation layer, and the heavy wall keeps acting as a thermal store. But in much of the German Altbau stock, the outside wall simply is not available to you — and that is where Innendämmung (interior insulation) enters, bringing the most demanding physics of any retrofit measure with it.

Why the outside wall is off-limits for many Altbaus

There are four common reasons, and most affected buildings have at least one of them:

The result is paradoxical: the buildings that would benefit most from insulation are often the ones least allowed to have it on the outside. Interior insulation is then the only remaining path — or the honest answer is to do less, but correctly (see what the grandfathering rules let you skip).

The physics in plain words

A solid brick wall with 40–60 cm of thickness holds a surprising amount of heat. Insulate it from the inside and you pull that warmth away: the wall behind the insulation becomes cold — close to outdoor temperature, in fact. Three consequences follow:

This is why "just stick foam on it" is the mould recipe, not a renovation. Every interior insulation job is a moisture-management design first and a thermal upgrade second.

Advertisement

Materials compared

No single material wins; each occupies a niche defined by thickness, vapour behaviour and budget. Rough 2026 ranges for material plus installation — treat them as orientation, not quotes:

MaterialThickness for a meaningful effectCost per m² (material + install)Vapour behaviourBest use
Mineral insulation board (e.g. special calcium-silicate or mineral foam boards)4–10 cmroughly €90–180capillary-active, very openGood all-rounder for breathable walls, mould-prone corners
Calcium silicate board (CaSi)2–10 cmroughly €120–220highly capillary-active, buffers moistureWhere mould remediation and insulation happen in one step; tight rooms
Wood fibre board4–10 cmroughly €100–190open to diffusion, moisture-bufferingEcological renovations, timber-friendly walls, good summer heat protection
Perlite board3–8 cmroughly €80–160open to diffusion, non-combustibleFire-sensitive areas, damp-prone basements and ground floors
Vacuum insulation panels (VIP)2–4 cmroughly €250–400effectively vapour-tightOnly where every centimetre counts — reveals, niches; unforgiving if pierced

The thin-but-expensive panels (CaSi, VIP) trade cost for space — decisive in rooms where losing 10 cm on each wall already hurts. The breathable boards cost less to run and forgive planning mistakes; the vapour-tight ones do not forgive anything. Experiences from completed Altbau projects point the same way again and again: the material matters less than whether the system was planned as a whole.

The detailing that decides success

Ask anyone who has done this: the failure points are never the middle of the wall. They are:

This detailing is also where quotes differ most. A cheap bid that skips the reveals and junctions is not cheaper — it is a deferred mould case.

Costs: a worked example

Take a typical Altbau room situation: 50 m² of exterior wall in a third-floor flat, one window wall with two deep reveals, eight sockets to relocate. Rough 2026 ranges, fully installed by a specialist firm:

ScenarioSystemPrice range (50 m² wall)What moves it
LowPerlite or mineral board, 4–6 cm, minimal detailingroughly €4,500–7,000Straight walls, few sockets, accessible room
TypicalWood fibre or mineral board, 6–8 cm, reveals and junctions includedroughly €7,000–12,000Scaffolding-free interior work, standard detailing
HighCaSi, 6–10 cm, full airtightness concept, VIP revealsroughly €12,000–20,000High ceilings, many sockets, tight stairwell access, mould remediation bundled in

What reliably moves the number upwards: working heights (scaffolding inside a 4-metre room), the number of sockets and switches, deep reveals needing thin specialty panels, wallpaper and panelling to remove, and — the classic Altbau surprise — walls that turn out to be more uneven than any board will tolerate. For context against the rest of the budget, see what heating actually costs and the full renovation budget breakdown.

GEG and the U-value: what it "counts" for

The GEG (Building Energy Act) sets target U-values for exterior walls — for new insulation on old masonry, roughly in the region of U ≤ 0.24 W/(m²K) as a reference value for full upgrades. Here is the honest answer:

Realistic outcome with 6–8 cm on a solid brick wall: the U-value drops from somewhere around 1.3–1.7 W/(m²K) to roughly 0.35–0.5 W/(m²K). Not new-build standard — but combined with a sensible heating strategy, it changes how the rooms feel and what the heating bill does.

When to skip it

Interior insulation is invasive, expensive per U-point and unforgiving. Consider not doing it when:

Wall surfaces under renovation — the phase where reveals, junctions and socket positions are decided. Photo: Pexels (license-free)
Mould appearing AFTER insulating?

It almost never comes from the material — it comes from missed details. The usual suspects: uninsulated or badly sealed window reveals (cold frame around the glass), thermal bridges at ceiling and floor edges left bare, leaky socket boxes and cable ducts pushing warm humid air into the cold wall, and vapour-tight layers stopping the wall from drying outwards. Diagnose the exact spot before re-opening anything: our guide to damp and mould in the Altbau covers the patterns, and the glossary explains terms like capillary-active and diffusion-open.

Advertisement

Planning work on an old building?

Windows, wiring, heating, floors — model every line item before you get quotes.

Open the calculator

Cost and material figures are rough orientation ranges for 2026 and vary by region, wall condition and firm. Interior insulation should be planned with a qualified energy consultant. Questions for the editors: hello@altbau.com